The egyptian TDC is located at the
Water Research & Pollution Control Department, National Research Centre, Dokki, Cairo, Egypt (NRC).
TDC layout
Segregated Wastewater produced by a nearby building is treated in 2 parallel lines
Black Water:
common primary treatment by a 3 chambers septic tank - the primary sludge is treated in a sludge drying reed bed
secondary treatment in 3 parallel lines by:
1)Constructed Wetalnds hybrid system: HF+VF
2) MBR
3) VF CW

---> click here to enlarge <---
Grey Water:
common primary treatment by a degreaser
secondary treatment in 2 parallel lines by:
1) HF CW
2) SBR
 
Monitoring results
- |